Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Ann Am Thorac Soc ; 20(5): 660-667, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36508316

RESUMEN

Rationale: Artificial intelligence (AI)-assisted diagnosis imparts high accuracy to chest radiography (CXR) interpretation; however, its benefit for nonradiologist physicians in detecting lung lesions on CXR remains unclear. Objectives: To investigate whether AI assistance improves the diagnostic performance of physicians for CXR interpretation and affects their clinical decisions in clinical practice. Methods: We randomly allocated eligible patients who visited an outpatient clinic to the intervention (with AI-assisted interpretation) and control (without AI-assisted interpretation) groups. Lung lesions on CXR were recorded by seven nonradiologists with or without AI assistance. The reference standard for lung lesions was established by three radiologists. The primary and secondary endpoints were the physicians' diagnostic accuracy and clinical decision, respectively. Results: Between October 2020 and May 2021, 162 and 161 patients were assigned to the intervention and control groups, respectively. The area under the receiver operating characteristic curve was significantly larger in the intervention group than in the control group for the CXR level (0.840 [95% confidence interval (CI), 0.778-0.903] vs. 0.718 [95% CI, 0.640-0.796]; P = 0.017) and lung lesion level (0.800 [95% CI, 0.740-0.861] vs. 0.677 [95% CI, 0.605-0.750]; P = 0.011). The intervention group had higher sensitivity in terms of both CXR and lung lesion level and a lower false referral rate for the lung lesion level. AI-assisted CXR interpretation did not affect the physicians' clinical decisions. Conclusions: AI-assisted CXR interpretation improves the diagnostic performance of nonradiologist physicians in detecting abnormal lung findings. Clinical trial registered with Clinical Research Information Service of the Republic of Korea (KCT 0005466).


Asunto(s)
Inteligencia Artificial , Radiografía Torácica , Humanos , Estudios Prospectivos , Radiografía , Pulmón
2.
Korean J Radiol ; 23(10): 1009-1018, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36175002

RESUMEN

OBJECTIVE: This study aimed to investigate the feasibility of using artificial intelligence (AI) to identify normal chest radiography (CXR) from the worklist of radiologists in a health-screening environment. MATERIALS AND METHODS: This retrospective simulation study was conducted using the CXRs of 5887 adults (mean age ± standard deviation, 55.4 ± 11.8 years; male, 4329) from three health screening centers in South Korea using a commercial AI (Lunit INSIGHT CXR3, version 3.5.8.8). Three board-certified thoracic radiologists reviewed CXR images for referable thoracic abnormalities and grouped the images into those with visible referable abnormalities (identified as abnormal by at least one reader) and those with clearly visible referable abnormalities (identified as abnormal by at least two readers). With AI-based simulated exclusion of normal CXR images, the percentages of normal images sorted and abnormal images erroneously removed were analyzed. Additionally, in a random subsample of 480 patients, the ability to identify visible referable abnormalities was compared among AI-unassisted reading (i.e., all images read by human readers without AI), AI-assisted reading (i.e., all images read by human readers with AI assistance as concurrent readers), and reading with AI triage (i.e., human reading of only those rendered abnormal by AI). RESULTS: Of 5887 CXR images, 405 (6.9%) and 227 (3.9%) contained visible and clearly visible abnormalities, respectively. With AI-based triage, 42.9% (2354/5482) of normal CXR images were removed at the cost of erroneous removal of 3.5% (14/405) and 1.8% (4/227) of CXR images with visible and clearly visible abnormalities, respectively. In the diagnostic performance study, AI triage removed 41.6% (188/452) of normal images from the worklist without missing visible abnormalities and increased the specificity for some readers without decreasing sensitivity. CONCLUSION: This study suggests the feasibility of sorting and removing normal CXRs using AI with a tailored cut-off to increase efficiency and reduce the workload of radiologists.


Asunto(s)
Inteligencia Artificial , Radiólogos , Adulto , Estudios de Cohortes , Humanos , Masculino , Estudios Retrospectivos , Triaje
3.
PLoS One ; 17(2): e0264383, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35202417

RESUMEN

PURPOSE: Lunit INSIGHT CXR (Lunit) is a commercially available deep-learning algorithm-based decision support system for chest radiography (CXR). This retrospective study aimed to evaluate the concordance rate of radiologists and Lunit for thoracic abnormalities in a multicenter health screening cohort. METHODS AND MATERIALS: We retrospectively evaluated the radiology reports and Lunit results for CXR at several health screening centers in August 2020. Lunit was adopted as a clinical decision support system (CDSS) in routine clinical practice. Subsequently, radiologists completed their reports after reviewing the Lunit results. The DLA result was provided as a color map with an abnormality score (%) for thoracic lesions when the score was greater than the predefined cutoff value of 15%. Concordance was achieved when (a) the radiology reports were consistent with the DLA results ("accept"), (b) the radiology reports were partially consistent with the DLA results ("edit") or had additional lesions compared with the DLA results ("add"). There was discordance when the DLA results were rejected in the radiology report. In addition, we compared the reading times before and after Lunit was introduced. Finally, we evaluated systemic usability scale questionnaire for radiologists and physicians who had experienced Lunit. RESULTS: Among 3,113 participants (1,157 men; mean age, 49 years), thoracic abnormalities were found in 343 (11.0%) based on the CXR radiology reports and 621 (20.1%) based on the Lunit results. The concordance rate was 86.8% (accept: 85.3%, edit: 0.9%, and add: 0.6%), and the discordance rate was 13.2%. Except for 479 cases (7.5%) for whom reading time data were unavailable (n = 5) or unreliable (n = 474), the median reading time increased after the clinical integration of Lunit (median, 19s vs. 14s, P < 0.001). CONCLUSION: The real-world multicenter health screening cohort showed a high concordance of the chest X-ray report and the Lunit result under the clinical integration of the deep-learning solution. The reading time slight increased with the Lunit assistance.


Asunto(s)
Aprendizaje Profundo , Radiografía Torácica/métodos , Radiólogos , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Radiografía Torácica/normas , Estudios Retrospectivos
4.
Eur Radiol ; 32(5): 3469-3479, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34973101

RESUMEN

OBJECTIVES: We aim ed to evaluate a commercial artificial intelligence (AI) solution on a multicenter cohort of chest radiographs and to compare physicians' ability to detect and localize referable thoracic abnormalities with and without AI assistance. METHODS: In this retrospective diagnostic cohort study, we investigated 6,006 consecutive patients who underwent both chest radiography and CT. We evaluated a commercially available AI solution intended to facilitate the detection of three chest abnormalities (nodule/masses, consolidation, and pneumothorax) against a reference standard to measure its diagnostic performance. Moreover, twelve physicians, including thoracic radiologists, board-certified radiologists, radiology residents, and pulmonologists, assessed a dataset of 230 randomly sampled chest radiographic images. The images were reviewed twice per physician, with and without AI, with a 4-week washout period. We measured the impact of AI assistance on observer's AUC, sensitivity, specificity, and the area under the alternative free-response ROC (AUAFROC). RESULTS: In the entire set (n = 6,006), the AI solution showed average sensitivity, specificity, and AUC of 0.885, 0.723, and 0.867, respectively. In the test dataset (n = 230), the average AUC and AUAFROC across observers significantly increased with AI assistance (from 0.861 to 0.886; p = 0.003 and from 0.797 to 0.822; p = 0.003, respectively). CONCLUSIONS: The diagnostic performance of the AI solution was found to be acceptable for the images from respiratory outpatient clinics. The diagnostic performance of physicians marginally improved with the use of AI solutions. Further evaluation of AI assistance for chest radiographs using a prospective design is required to prove the efficacy of AI assistance. KEY POINTS: • AI assistance for chest radiographs marginally improved physicians' performance in detecting and localizing referable thoracic abnormalities on chest radiographs. • The detection or localization of referable thoracic abnormalities by pulmonologists and radiology residents improved with the use of AI assistance.


Asunto(s)
Inteligencia Artificial , Radiografía Torácica , Estudios de Cohortes , Humanos , Pacientes Ambulatorios , Estudios Prospectivos , Radiografía , Radiografía Torácica/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad
6.
PLoS One ; 16(2): e0246472, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33606779

RESUMEN

PURPOSE: This study evaluated the performance of a commercially available deep-learning algorithm (DLA) (Insight CXR, Lunit, Seoul, South Korea) for referable thoracic abnormalities on chest X-ray (CXR) using a consecutively collected multicenter health screening cohort. METHODS AND MATERIALS: A consecutive health screening cohort of participants who underwent both CXR and chest computed tomography (CT) within 1 month was retrospectively collected from three institutions' health care clinics (n = 5,887). Referable thoracic abnormalities were defined as any radiologic findings requiring further diagnostic evaluation or management, including DLA-target lesions of nodule/mass, consolidation, or pneumothorax. We evaluated the diagnostic performance of the DLA for referable thoracic abnormalities using the area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, and specificity using ground truth based on chest CT (CT-GT). In addition, for CT-GT-positive cases, three independent radiologist readings were performed on CXR and clear visible (when more than two radiologists called) and visible (at least one radiologist called) abnormalities were defined as CXR-GTs (clear visible CXR-GT and visible CXR-GT, respectively) to evaluate the performance of the DLA. RESULTS: Among 5,887 subjects (4,329 males; mean age 54±11 years), referable thoracic abnormalities were found in 618 (10.5%) based on CT-GT. DLA-target lesions were observed in 223 (4.0%), nodule/mass in 202 (3.4%), consolidation in 31 (0.5%), pneumothorax in one 1 (<0.1%), and DLA-non-target lesions in 409 (6.9%). For referable thoracic abnormalities based on CT-GT, the DLA showed an AUC of 0.771 (95% confidence interval [CI], 0.751-0.791), a sensitivity of 69.6%, and a specificity of 74.0%. Based on CXR-GT, the prevalence of referable thoracic abnormalities decreased, with visible and clear visible abnormalities found in 405 (6.9%) and 227 (3.9%) cases, respectively. The performance of the DLA increased significantly when using CXR-GTs, with an AUC of 0.839 (95% CI, 0.829-0.848), a sensitivity of 82.7%, and s specificity of 73.2% based on visible CXR-GT and an AUC of 0.872 (95% CI, 0.863-0.880, P <0.001 for the AUC comparison of GT-CT vs. clear visible CXR-GT), a sensitivity of 83.3%, and a specificity of 78.8% based on clear visible CXR-GT. CONCLUSION: The DLA provided fair-to-good stand-alone performance for the detection of referable thoracic abnormalities in a multicenter consecutive health screening cohort. The DLA showed varied performance according to the different methods of ground truth.


Asunto(s)
Algoritmos , Aprendizaje Profundo , Radiografía Torácica/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Curva ROC , Estudios Retrospectivos
7.
Clin Exp Emerg Med ; 8(4): 336-339, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35000362

RESUMEN

Epidural hematoma with Brown-Sequard syndrome caused by an epidural injection is a rarely found condition in the emergency department (ED). We report an unusual case of Brown-Sequard syndrome in a 55-year-old man who presented at the ED with right-sided weakness and contralateral loss of pain and temperature sensation after a cervical epidural injection for shoulder pain. Cervicla spine magnetic resonance imaging showed an epidural hematoma from C4 to C6. After admission, his right hemiparesis and contralateral sensory loss improved within eight days, and surgical decompression was not required. Diagnosing spinal lesions in the ED is challenging, especially in patients with acute neurological signs requiring immediate evaluation for stroke. In this case, definite hemiparesis and some contralateral sensory loss were noted. Therefore, a potential spinal lesion was suspected rather than a stroke. This case emphasized the importance of conducting a focused neurological examination after history taking.

8.
Artículo en Inglés | MEDLINE | ID: mdl-31781047

RESUMEN

Background: Benign thyroid follicular tumors without histological evidence of carcinoma can metastasize. However, the pathogenesis of metastasis remains unclear. Here, the new proposed terminology, "non-invasive follicular thyroid neoplasm with papillary-like nuclear features" should be considered. We present a case of an encapsulated type of follicular variant of papillary thyroid carcinoma (FVPTC) that exhibited distant lung and brain metastases and was initially diagnosed as follicular adenoma. Case Report: In December 2006, a 64-year-old woman underwent ultrasonography-guided fine-needle aspiration of the right thyroid nodule at our hospital because of a palpable right neck mass. Right lobectomy was performed, and a follicular adenoma was diagnosed. In October 2015, she visited our hospital owing to dry cough and mild dyspnea and underwent computed tomography-guided transthoracic core needle biopsy for the lung nodule owing to probably multiple lung metastasis on chest X-ray and computed tomography. Based on retrospective analysis of the primary thyroid tumor and lung nodule specimen, an encapsulated follicular variant of papillary thyroid carcinoma with lung metastasis was confirmed. Conclusion: We report a case of an encapsulated follicular variant of papillary thyroid carcinoma with unexpected metastasis to the lung 9 years after thyroid surgery in a patient who was initially diagnosed as follicular adenoma. A careful close follow-up with re-examination of the histopathology specimen may be needed in patients who were diagnosed with benign thyroid follicular tumors.

9.
Med Sci Monit ; 25: 6943-6949, 2019 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-31522188

RESUMEN

BACKGROUND This study aimed to assess the utility and characteristics of preoperative ultrasonography (US) in patients transferred to referral hospitals from local clinics with a diagnosis of malignancy on US-guided fine-needle aspiration cytology of thyroid nodules. MATERIAL AND METHODS From January 2018 to June 2018, 109 transferred patients underwent preoperative US in our hospital for suspected thyroid malignancy on cytological analysis after US-guided fine-needle aspiration of thyroid nodules in local clinics. Preoperative US was performed by a single radiologist in all patients. Among them, 6 were excluded from the study because of refusal of thyroid surgery. Preoperative US and histopathological results were compared in all patients. RESULTS After thyroid surgery, pathological examination revealed papillary thyroid carcinoma (PTC) (n=98), follicular adenoma (n=1), and nodular hyperplasia (n=4). Of the 103 patients, 91 exhibited suspicious US findings on the preoperative US, whereas 12 did not. In the 91 patients with suspicious US findings, PTC (n=90) and follicular adenoma (n=1) were confirmed after thyroid surgery. In the 12 patients with no suspicious US findings, PTC (n=8) and nodular hyperplasia (n=4) were confirmed after thyroid surgery. On repeat analysis of the cytological slides of the 4 nodular hyperplasia cases from the local clinics, Bethesda category II (n=1) and III (n=3) were determined. CONCLUSIONS In the transferred patients with a malignant cytology, preoperative US might be helpful to detect false-positive cytology cases.


Asunto(s)
Cuidados Preoperatorios , Utilización de Procedimientos y Técnicas , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía , Adolescente , Adulto , Anciano , Biopsia con Aguja Fina , Carcinoma Papilar/diagnóstico por imagen , Carcinoma Papilar/patología , Carcinoma Papilar/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Transferencia de Pacientes , Estudios Retrospectivos , Glándula Tiroides/cirugía , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/cirugía , Nódulo Tiroideo/cirugía , Adulto Joven
10.
Sci Rep ; 9(1): 7027, 2019 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-31065031

RESUMEN

In ultrasound (US)-guided fine-needle aspiration (FNA) of solid thyroid nodules (STN) using liquid-based cytology (LBC), the most appropriate needle size for LBC remains unclear. This study compared the cytological adequacy and complications associated with using 23- and 25-gauge needles in US-guided FNA of STNs using LBC. US-guided FNA was performed in consecutive patients by one radiologist to diagnose STNs ≥ 5 mm in the largest diameter. The one-sampling technique through a single needle puncture and multiple to-and-fro needle motions was used in each patient. The 23- and 25-guage needles were used consecutively each day. After FNA, the pain and complications experienced by each patient were investigated by a nurse, who was blinded to the information of needle gauge used. A cytopathologist retrospectively analyzed the cytological adequacy and cellularity of the cases. Of the 99 STNs, eight (8.1%) exhibited inadequate cytology (4 each with 23- and 25-gauge needles). The rate of cytological adequacy was not statistically different between the groups (p = 0.631). The mean pain scale values with 23- and 25-gauge needles were 2.1 ± 1.3 and 1.6 ± 1.3, respectively (p = 0.135). There were no significant complications in either group. In conclusion, both 23- and 25-gauge needles are useful in LBC because cytological adequacy and complications were not statistically different with both sizes of the needles.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Biopsia Líquida/instrumentación , Dolor/diagnóstico , Nódulo Tiroideo/diagnóstico , Adulto , Anciano , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/efectos adversos , Femenino , Humanos , Biopsia Líquida/efectos adversos , Masculino , Persona de Mediana Edad , Dolor/etiología , Dimensión del Dolor , Estudios Prospectivos , Estudios Retrospectivos , Nódulo Tiroideo/patología
11.
J Vasc Interv Radiol ; 30(6): 807-812, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30930002

RESUMEN

PURPOSE: To evaluate the efficacy and safety of transvenous coil embolization of the venous sac for type II renal arteriovenous malformation (AVM). MATERIALS AND METHODS: A retrospective review was conducted of 8 patients (5 women and 3 men; mean age, 57 years; age range, 41-69 years) who underwent transvenous coil embolization for type II congenital renal AVM at 5 different hospitals between 2012 and 2018. Additional intra-arterial ethanol injection was performed if shunt flow persisted after venous sac coiling. Technical success was defined as complete occlusion of shunt flow with coil embolization. Clinical success was defined as no symptom recurrence during the follow-up period. The renal parenchymal infarction rate was measured on computed tomography (CT), and procedure-related complications were reviewed. RESULTS: Nine sessions of embolization were performed for 8 patients. The mean venous sac size was 24 mm (range, 10-39 mm), and a mean of 14 micro and/or micro-detachable coils (range, 3-50) were used. The technical success rate was 88% (7 of 8) using coil embolization. One patient (12%) required additional ethanol injection to complete occlusion of the shunt flow and had a less than 10% parenchymal infarction on follow-up CT. No procedure-related complications or recurrences occurred during a mean clinical follow-up period of 20.8 months (range, 4.7-76.6 months). CONCLUSIONS: Transvenous coil embolization of type II renal AVM showed an 88% technical success rate. One patient (12%) showed less than 10% renal parenchymal infarction after additional ethanol injection. No additional complications or recurrences occurred during the follow-up period.


Asunto(s)
Malformaciones Arteriovenosas/terapia , Embolización Terapéutica/instrumentación , Arteria Renal/anomalías , Venas Renales/anomalías , Adulto , Anciano , Malformaciones Arteriovenosas/diagnóstico por imagen , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Renal/diagnóstico por imagen , Venas Renales/diagnóstico por imagen , República de Corea , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
12.
Artículo en Inglés | MEDLINE | ID: mdl-30574121

RESUMEN

Background: No previous studies have investigated the feasibility of magnetic resonance imaging (MRI) diagnosis for detecting incidental diffuse thyroid disease (DTD). This study investigated MRI features of normal thyroid parenchyma and incidental DTD. Methods: From January 2008 to December 2017, 387 patients underwent neck MRI in our hospital due to tumor/nodal staging (n = 137), lymphadenopathy (n = 122), inflammatory neck lesion (n = 85), congenital neck lesion (n = 12), and patient request (n = 31). Among them, 375 patients were excluded because of a lack of appropriate histopathological data on the thyroid parenchyma. Results: Among the patients included, 10 had normal thyroid parenchyma, 1 had Hashimoto thyroiditis, and 1 had diffuse hyperplasia. The common MRI features of normal thyroid parenchyma include iso-/slightly high and homogeneous signal intensity on T1/T2-weighted images, normal anteroposterior diameter of the thyroid gland, smooth margin, and homogeneously increased enhancement as compared to adjacent muscle. Hashimoto thyroiditis exhibited high and inhomogeneous signal intensity on T2-weighted images, while diffuse hyperplasia revealed an increased anteroposterior diameter and lobulated margin of the thyroid gland, and inhomogeneous enhancement. Conclusions: MRI may be helpful for detection of incidental DTD.

13.
Medicine (Baltimore) ; 97(34): e12050, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30142857

RESUMEN

RATIONALE: Based on imaging and biopsy results, surgical removal of mediastinal nodular hyperplasia (MNH) may be unnecessary, and mediastomy may be avoidable. PATIENT CONCERNS: We report three cases of nodular hyperplasia presenting as a mediastinal mass on imaging studies during a health check-up or for the evaluation of known abscess in the right masticator and submandibular spaces. INTERVENTIONS: In the first two cases, surgical excision was performed, and in the third case, US-guided core needle biopsy was performed. DIAGNOSES: Histopathological examination revealed MNH in the first two cases, and histologic examination suggested MNH. OUTCOMES: In the first two cases, there were no associated complications after successful surgical removal. In the third case, surgery was not performed because of old age and no associated symptoms. LESSONS: MNH may mimic mediastinal tumors on imaging studies. Accordingly, awareness of imaging features, interval changes, associated symptoms, and biopsy results may be necessary for the appropriate management of MNH.


Asunto(s)
Neoplasias del Mediastino/diagnóstico , Mediastino/patología , Nódulo Tiroideo/diagnóstico , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Hiperplasia/diagnóstico , Persona de Mediana Edad , Nódulo Tiroideo/patología
14.
Artículo en Inglés | MEDLINE | ID: mdl-29867759

RESUMEN

BACKGROUND: The ultrasonographic characteristics and difference for various subtypes of papillary thyroid carcinoma (PTC) are still unclear. The aim of this study was to compare the ultrasonographic features of PTC according to its subtype in patients undergoing thyroid surgery. METHODS: In total, 140 patients who underwent preoperative thyroid ultrasonography (US) and thyroid surgery between January 2016 and December 2016 were included. The ultrasonographic features and the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) category of each thyroid nodule were retrospectively evaluated by a single radiologist, and differences in ultrasonographic features according to the PTC subtype were assessed. RESULTS: According to histopathological analyses, there were 97 classic PTCs (62.2%), 34 follicular variants (21.8%), 5 tall cell variants (3.2%), 2 oncocytic variants (1.3%), 1 Warthin-like variant (0.6%), and 1 diffuse sclerosing variant (0.6%). Most PTCs were classified under K-TIRADS category 5. Among the ultrasonographic features, the nodule margin and the presence of calcification were significantly different among the PTC subtypes. A spiculated/microlobulated margin was the most common type of margin, regardless of the PTC subtype. In particular, all tall cell variants exhibited a spiculated/microlobulated margin. The classic PTC group exhibited the highest prevalence of intranodular calcification, with microcalcification being the most common. The prevalence of multiplicity and nodal metastasis was high in the tall cell variant group. CONCLUSION: The majority of PTCs in the present study belonged to K-TIRADS category 5, regardless of the subtype. Our findings suggest that ultrasonographic features are not useful for distinguishing PTC subtypes.

15.
BMC Med Imaging ; 18(1): 12, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29764382

RESUMEN

BACKGROUND: This study aimed to assess the appropriate number of sessions and interval of routine follow-up ultrasonography (US) in patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC). METHODS: Between January 2008 and December 2009, 569 patients underwent total thyroidectomy for PTC. Of the 569 patients, 44 were excluded from the study because of no US follow-up data for the neck (n = 43) or owing to indeterminate tumor recurrence/persistence (n = 1). The follow-up US for all the patients was performed by a single radiologist. Based on the cytohistopathological results, tumor recurrence/persistence was determined. RESULTS: In the 525 patients, the mean interval to the last follow-up US was 54.7 months, and the mean number of follow-up US sessions was 4.4. Of the 525 patients, 31 (5.9%) showed nodal (n = 30) and non-nodal (n = 1) tumor recurrence/persistence. Patient age and N stage were independently associated with tumor recurrence/persistence. Among patients showing tumor recurrence/persistence after total thyroidectomy, the time at first detection of suspicious US findings on follow-up US was ≤8 months in 2 patients, between 10 and 23 months in 21, and ≥ 25 months in 8. In a receiver operating characteristic curve analysis, the number of sessions and interval of the provided follow-up US were inappropriate for the detection of tumor recurrence/persistence. CONCLUSIONS: For the detection of tumor recurrence/persistence after total thyroidectomy in PTC patients, routine US follow-up with a 1- or 2-year interval may be excessive.


Asunto(s)
Recurrencia Local de Neoplasia/diagnóstico por imagen , Cáncer Papilar Tiroideo/diagnóstico por imagen , Cáncer Papilar Tiroideo/cirugía , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Pruebas Diagnósticas de Rutina , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/epidemiología , Curva ROC , Cáncer Papilar Tiroideo/epidemiología , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/cirugía , Neoplasias de la Tiroides/epidemiología , Tiroidectomía , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía , Adulto Joven
16.
Artículo en Inglés | MEDLINE | ID: mdl-29593648

RESUMEN

BACKGROUND: No previous study has employed the frequency and interval of follow-up ultrasonography (US) during the first 10 years after total thyroidectomy in patients with papillary thyroid carcinoma (PTC). The aim of this study was to determine the appropriate frequency and interval of follow-up US during the first 10 years in patients who have undergone total thyroidectomy for PTC. METHODS: Two hundred seventy-two patients underwent total thyroidectomy for PTC at our institution from January 2006 to December 2007. Nineteen patients were excluded because of lack of US follow-up data for the neck. Follow-up US was performed by one of two radiologists in all patients. Tumor recurrence/persistence was confirmed by histopathology. RESULTS: The mean interval between surgery and the final follow-up US examination was 79.0 months, and the mean number of follow-up US sessions was 5.9 in the 253 evaluable patients. Eleven patients (4.3%) developed tumor recurrence/persistence, which was detected on follow-up US within 5 years after total thyroidectomy in all cases. T and N stages were independently associated with tumor recurrence/persistence. The interval between surgery and first suspicion of tumor recurrence/persistence on follow-up US was ≤12 months in six patients and 20, 35, 41, 53, and 60 months in the remaining five patients. CONCLUSION: For detection of tumor recurrence/persistence after total thyroidectomy in patients with PTC, one or two sessions of follow-up US during the first 2 years, depending on T and N stages and one session of follow-up US in every second year during the following 8 years may be appropriate.

17.
Surg Radiol Anat ; 40(2): 237-240, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28988293

RESUMEN

Persistent trigeminal artery (PTA) is a rare cerebrovascular variation of remnant fetal carotid-vertebrobasilar anastomoses. The PTA variant terminates in the cerebellar artery with no direct connection to the basilar artery. We present a rare case of a PTA variant that terminated directly into the ipsilateral posterior inferior cerebellar artery.


Asunto(s)
Cerebelo/irrigación sanguínea , Arterias Cerebrales/anomalías , Aneurisma Intracraneal/diagnóstico por imagen , Accidentes de Tránsito , Angiografía de Substracción Digital , Femenino , Humanos , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Persona de Mediana Edad
18.
Sci Rep ; 7(1): 11930, 2017 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-28931854

RESUMEN

We experimentally demonstrate strongly enhanced coupling between excited magnons in an Yttrium Iron Garnet (YIG) film and microwave photons in an inverted pattern of split-ring resonator (noted as ISRR). The anti-crossing effects of the ISRR's photon mode and the YIG's magnon modes were found from |S21|-versus-frequency measurements for different strengths and directions of externally applied magnetic fields. The spin-number-normalized coupling strength (i.e. single spin-photon coupling) [Formula: see text] was determined to 0.194 Hz ([Formula: see text] = 90 MHz) at 3.7 GHz frequency. Furthermore, we found that additional fine features in the anti-crossing region originate from the excitation of different spin-wave modes (such as the magnetostatic surface and the backward-volume magnetostatic spin-waves) rather than the Kittel-type mode. These spin-wave modes, as coupled with the ISRR mode, modify the anti-crossing effect as well as their coupling strength. An equivalent circuit model very accurately reproduced the observed anti-crossing effect and its coupling strength variation with the magnetic field direction in the planar-geometry ISRR/YIG hybrid system. This work paves the way for the design of new types of high-gain magnon-photon coupling systems in planar geometry.

19.
Opt Lett ; 42(16): 3076-3079, 2017 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-28809876

RESUMEN

We present the first sub-100 fs bulk solid-state laser in the 2-µm spectral range employing the monoclinic Tm3+-dopedMgWO4 crystal as an active medium. By applying a graphene-based saturable absorber and chirped mirrors for dispersion management, stable self-starting mode-locked operation at 2017 nm was achieved. Nearly Fourier-limited pulses as short as 86 fs featuring a bandwidth of 53 nm were generated at a repetition rate of 76 MHz. A pulse energy of 1.1 nJ was achieved at 87 MHz for a pulse duration of 96 fs. The mode-locked Tm3+:MgWO4 laser exhibits excellent stability with a fundamental beat note extinction ratio of 80 dBc above noise level.

20.
Sci Rep ; 7: 45185, 2017 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-28327624

RESUMEN

We report on a micromagnetic numerical simulation study of dynamic coupling between neighboring skyrmions periodically arranged in narrow-width nanostrips. We explored the coupled gyration modes and their characteristic dispersions in terms of the interdistance between the neighboring skyrmions. The application of perpendicular magnetic fields allows for the control and modification of the dispersion of the coupled gyration modes. The coupled gyration modes of individual skyrmions might provide a new type of information carrier in narrow-width straight and curved nanostrips, as driven by magnetic interactions in such continuous thin films.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...